Here 1 ammeter at the output of the generator, the other after the regulator

00:10.079 --> 00:18.548
The red voltmeter shows the voltage coming into the motor

00:18.548 --> 00:24.353
3 V * 0.4 A = 1.2 Watt for the engine

00:24.353 --> 00:34.672
Power consumption: 28 V * .44 Amps = 12 Watts! 10 times +!

00:34.672 --> 00:42.168
And yes ! regulation series! Yield = Us / Ue = here 10% (Ps / Pe = also 10%)

00:42.168 --> 00:49.827
Here Ps = 3.5 Watt (7 V * 0.5 A), Pe = 15 W (30 V * 0.5 A). Ps / Pe = 23% as 7/30

00:49.827 --> 01:09.045
Last measurement: 12 V * 0.5 A = 6 W, 30 V * 0.5 A = 15 W, yield = 33%

01:09.045 --> 01:32.233
The efficiency is equal to Us / Ue, neglecting the intrinsic consumption of the regulator

01:32.233 --> 01:45.763
If I bring Ue closer to Us, the yield is good: 12/14 = about 80%

01:45.763 --> 02:01.440
The laser thermometer reads 55 ° C! Poor performance = warm-up!

02:01.440 --> 02:13.100
55 ° C against 28 ° C ambient (sorry Tecnipass is in the South :-))