00:00.000 --> 00:07.690
Power thyristor with fine wire trigger, the rest resembles the diode (mounting ...)

00:07.690 --> 00:16.261
Here a double thyristor (for mixed bridge ...) 2 triggers up

00:16.261 --> 00:23.246
Sole of the module to be attached to a heatsink

00:23.246 --> 00:34.389
The thyristor is in series with the lamp to control it

00:34.389 --> 00:44.641
The potentiometer will make it possible to control the trigger current of the thyristor

00:44.641 --> 00:51.846
Trigger intensity (red ammeter on the right) increases

00:51.846 --> 00:57.158
Shortly after 2.4 mA: tripping

00:57.158 --> 01:04.647
When the thyristor conducts, the intensity in the trigger decreases and reverses

01:04.647 --> 01:13.768
Maintaining Ig trigger is useless. To cut, the power supply must be interrupted

01:13.768 --> 01:42.130
By proceeding slowly we measured almost 7 mA to trigger it

01:42.130 --> 01:59.774
Use the value of the 'pessimistic' datasheet to be certain that it will trigger (10 MA here)

01:59.774 --> 02:14.767
No reverse conduction!

02:14.767 --> 02:25.333
With a triac connected in 'inverse' also

02:25.333 --> 02:34.624
The triac is capable of triggering in all directions

02:34.624 --> 02:52.849
In this sense, 7 mA instead of 12 mA

02:52.849 --> 03:08.489
Self-holds for thyristor and triac. The triac is a double thyristor for the alternative